Knowledge Base

Meters - Overview, adding, and recording readings

Meters - Overview, adding, and recording readings

The Meters section allows users to manage and track utility meters by adding detailed information, such as MPAN, MPR, supplier details, serial numbers, and more. Users can log meter readings, which are stored in a database for tracking and reporting purposes. This functionality facilitates accurate monitoring of utility usage and helps streamline data management for better analysis and reporting.


The Meters Page

Meters is only accessible in the meters section, there are no widgets on the dashboard and they are not linked to in jobs or quotes.


There are a number of meter management options, that if you’re a meter administrator you will have access to:


As well as a list of the available meters which you can filter ibn the main section of the screen.


In order to add meters you will need to have populated some information in each of these sections:

  • Manufacturers – the manufacturer of the meter

  • Occupancy Types – the type of property, house, flat, commercial unit, warehouse etc.

  • Suppliers – the energy supplier – E-On, Scottish Power, Anglian Water etc.

  • Supply Type – Gas, Water, Electricity

  • Types – Digital, Analogue, Smart etc.

  • Units – kWh, L, Gallons etc.


Create a new meter by clicking Add.



Add new meter


Work your way through the form adding the information required, here is a guide of each of the fields, red items are mandatory:


  • Site – Choose the site for which you are creating the meter

  • Location – locations are pre set so choose from the drop down list, if a location is missing please contact helpdesk.cafm@vantify.com

  • Service Provider – this is the service provider who will be required to carry out the meter (if the meters are managed by an external service provider.)

  • Description – whilst not mandatory this is an important field and helps to identify what the meter is and where it is located.

  • Utility Consultant – if you use a utility consultant enter their details here, this is a freetype box.


Reference – this is the meter reference number (e.g. MPAN number, MPR number)

MPAN is a unique electricity meter number (Meter Point Administration Number) or can also be known as a supply number, this can be found on your bill

The MPAN number has a top line and a bottom line, 21 digits in total. The bottom line has 13 digits and top line has 8 digits (a lot of users exclude the top line of the MPAN). All MPANs will begin with the number 0. See example below of how a MPAN number is displayed and how this number has been made up. For the purpose of Vantify CAFM you will not need to know what each of these means:

  • MPR (Meter Point Reference) is a unique gas meter number relating to the pipework at the site, the number is usually between 6 and 10 digits long, this can be found on your bill.

  • Serial Number - Each meter has a meter serial number (normally a mix of numbers and letters) found on the front of the meter

  • Account Number – This is the supplier account number (found on utility bill)

  • Multiplier – This is a numeric field that is used to convert energy units. Enter the conversion multiplier if known.

  • Maximum value – enter the maximum value the meter will run to (9999.9 for example) if known

  • Type – This needs to be uploaded in advance of creating the meter and covers standard, prepayment, AMR / Smart meter, submeter, economy 7

  • Manufacturer – This needs to be uploaded in advance of creating the meter, if you know the manufacturer choose from the drop down list.

  • Utility provider - This needs to be uploaded in advance of creating the meter, so choose from the drop down who supplies the energy.

  • Supply Type - This needs to be uploaded in advance of creating the meter and covers gas, electricity, water

  • Meter Unit – This needs to be uploaded in advance of creating the meter and is the reading for example kWh

  • Occupancy – This needs to be uploaded in advance of creating the meter and covers the building occupancy such as landlord/tenant

  • Dual Rated - (yes/no) is it a single rate, or day/night dual rate meter

  • Automatically read – No if it is read manually, Yes if AMR or smart meter

  • Require file on meter readings – this will determine if an upload such as a photo is required when adding a meter reading. Yes/No

  • Tenant Utility Re-charge (TUR) - Tenant Utility Recharge, is the meter being charged to the tenant (yes/no)

  • Notes – a basic notes field

  • Frequency – The frequency of readings such as 1 Week, 1 month, 3 months.



Once created the meters would present this:



Adding a meter reading

Open the meter you are reading and click Add Reading.


Enter the date and time, the reading itself, whether it rolled over from a previous period and you can also upload an image.


Click Add and it will be added to the readings history list.


Adding a reading on the app


Open the app and navigate to the meters section:


You can filter the list using the filter icon at the top, otherwise open the meter in question:



Tap Click Add Reading using the plus in the bottom right:



Enter the date and time, and enter the reading (you can also add a photo if required:




This will be added to the list of readings.